Sol-Care Disposable IV Catheters Safety - Ported

Sol-Care Safety IV Catheters are developed to provide a vascular access to patients and at the same time reduce the risk of needle stick injuries. They are single-use indwelling device consisting of medical plastics, stainless steel needle and passive safety needle tip protection. They are offered witha soft polyurethane material, clear flashback chamber, anti-slips ribs and tab that helps on the catheter insertion and advancement with no technique change required by the user. For the quick addition of drugs, there is a port that can be opened and closed per access need. They are also color-code for easier catheter gauge identification, They are intended to be inserted into a patient’s peripheral vascular system for short term use of blood sampling or fluids administration.

They are compatible with ISO luers. Our products are Latex free, DEHP Free, non-toxic, non-pyrogenic and latex free

Indications: IV access to peripheral vascular system indicated for short term use to sample blood or administer fluid.

Intended user: Healthcare professional.

Precautions:

1. For proper use, clinicians must be trained in the practice of venipuncture and follow the INSTRUCTIONS FOR USE.

2. Observe Standard Precautions on all patients.

3. Aseptic technique, proper skin preparation, and continued protection of the insertion site are essential.

4. Product is sterile, non-toxic and non-pyrogenic unless package has been opened or damaged.

5. This product is DEHP free. This product does not contain natural rubber latex.

6. Single use only. Do not re-use.

7. Do not bend the needle when using the catheter system.

8. Do not use scissors at or near the insertion site.

9. Do not attempt to override or defeat the needle shielding mechanism.

10. Report needle sticks immediately and follow established protocol.

11. Immediately dispose of any needles that fail to shield, keeping the needlepoint away from the body and fingers at all times.

12. Do not attempt to reinsert a partially or completely withdrawn needle back into the catheter.

13. Re-use may lead to infection or other illness/injury.

14. Connectors used in conjunction with the product must comply with ISO 80369-7.

15. Luer connections should not be left unattended due to potential of disconnection.

16. It is recommended that the device be changed according to facility policy or if the integrity of the device has been compromised.

17. Follow current institutional policies and procedures for catheter insertion, maintenance and removal.

Sol-Care Disposable IV Catheters Safety - Straight & Winged

Safety - Straight

Sol-Care Safety IV Catheters are developed to provide a vascular access to patients and at the same time reduce the risk of needle stick injuries. They are single-use indwelling device consisting of medical plastics, stainless steel needle and passive safety needle tip protection. Available in two versions: straight with and without wings. Both versions are offered with soft polyurethane material, clear flashback chamber, anti-slips ribs and tab that helps on the catheter insertion and advancement with no technique change required by the user. They are designed to stand high pressure injection, up to 300psi. They are also color-code for easier catheter gauge identification, They are intended to be inserted into a patient’s peripheral vascular system for short term use of blood sampling or fluids administration.

They are compatible with ISO luers. Our products are Latex free, DEHP Free, non-toxic, non-pyrogenic and latex free

Indications: IV access to peripheral vascular system indicated for short term use to sample blood or administer fluid.

Intended user: Healthcare professional.

Precautions:

1. For proper use, clinicians must be trained in the practice of venipuncture and follow the

INSTRUCTIONS FOR USE

2. Observe Standard Precautions on all patients.

3. Aseptic technique, proper skin preparation, and continued protection of the insertion site are essential.

4. Product is sterile, non-toxic and non-pyrogenic unless package has been opened or damaged.

5. This product is DEHP free. This product does not contain natural rubber latex.

6. Single use only. Do not re-use.

7. Do not bend the needle when using the catheter system.

8. Do not use scissors at or near the insertion site.

9. Do not attempt to override or defeat the needle shielding mechanism.

10. Report needle sticks immediately and follow established protocol.

11. Immediately dispose of any needles that fail to shield, keeping the needlepoint away from the body and fingers at all times.

12. Do not attempt to reinsert a partially or completely withdrawn needle back into the catheter.

13. Re-use may lead to infection or other illness/injur y.

14. Connectors used in conjunction with the product must comply with ISO 80369-7.

15. Luer connections should not be left unattended due to potential of disconnection.

16. If the Disposable IV Catheter is indicated for power injection, catheter systems are suitable for use with power injectors set to a maximum pressure of 300 psi and within maximum flow rate recommendations (see table), when the Vent fitting is removed, and a direct connection is made.

17. The patency of the catheter system must be assured immediately before power injecting. Measures should be taken to avoid kinking or obstructing the catheter system during power injection to avoid product failure.

18. Use with power injector pressure greater than 300 psi may cause product leakage and/or damage to the product.

19. Ensure that the injector is properly calibrated and will automatically stop at a pressure which exceeds 300 psi.

20. When power injecting through the device with a luer adapter with dual port, replace any needleless cap on the unused port with a dead-end cap and tighten.

21. Flush the device using sterile normal saline prior to and immediately following the completion of power injection.

22. It is recommended that the device be changed according to facility policy or if the integrity of the device has been compromised.

23. Follow current institutional policies and procedures for catheter insertion, maintenance and removal.

24. The device can be used in the MRI environment.


Safety - Straight with wings

Sol-Care Safety IV Catheters are developed to provide a vascular access to patients and at the same time reduce the risk of needle stick injuries. They are single-use indwelling device consisting of medical plastics, stainless steel needle and passive safety needle tip protection. Available in two versions: straight with and without wings. Both versions are offered with soft polyurethane material, clear flashback chamber, anti-slips ribs and tab that helps on the catheter insertion and advancement with no technique change required by the user. They are designed to stand high pressure injection, up to 300psi. They are also color-code for easier catheter gauge identification, They are intended to be inserted into a patient’s peripheral vascular system for short term use of blood sampling or fluids administration.

They are compatible with ISO luers. Our products are Latex free, DEHP Free, non-toxic, non-pyrogenic and latex free

Indications: IV access to peripheral vascular system indicated for short term use to sample blood or administer fluid.

Intended user: Healthcare professional.

Precautions:

1. For proper use, clinicians must be trained in the practice of venipuncture and follow the

INSTRUCTIONS FOR USE

2. Observe Standard Precautions on all patients.

3. Aseptic technique, proper skin preparation, and continued protection of the insertion site are essential.

4. Product is sterile, non-toxic and non-pyrogenic unless package has been opened or damaged.

5. This product is DEHP free. This product does not contain natural rubber latex.

6. Single use only. Do not re-use.

7. Do not bend the needle when using the catheter system.

8. Do not use scissors at or near the insertion site.

9. Do not attempt to override or defeat the needle shielding mechanism.

10. Report needle sticks immediately and follow established protocol.

11. Immediately dispose of any needles that fail to shield, keeping the needlepoint away from the body and fingers at all times.

12. Do not attempt to reinsert a partially or completely withdrawn needle back into the catheter.

13. Re-use may lead to infection or other illness/injury.

14. Connectors used in conjunction with the product must comply with ISO 80369-7.

15. Luer connections should not be left unattended due to potential of disconnection.

16. If the Disposable IV Catheter is indicated for power injection, catheter systems are suitable for use with power injectors set to a maximum pressure of 300 psi and within maximum flow rate recommendations (see table), when the Vent fitting is removed, and a direct connection is made.

*Please include "Notes - Table Straight"

17. The patency of the catheter system must be assured immediately before power injecting. Measures should be taken to avoid kinking or obstructing the catheter system during power injection to avoid product failure.

18. Use with power injector pressure greater than 300 psi may cause product leakage and/or damage to the product.

19. Ensure that the injector is properly calibrated and will automatically stop at a pressure which exceeds 300 psi.

20. When power injecting through the device with a luer adapter with dual port, replace any needleless cap on the unused port with a dead-end cap and tighten.

21. Flush the device using sterile normal saline prior to and immediately following the completion of power injection.

22. It is recommended that the device be changed according to facility policy or if the integrity of the device has been compromised.

23. Follow current institutional policies and procedures for catheter insertion, maintenance and removal.

24. The device can be used in the MRI environment.

Sol-Care Disposable IV Catheters Safety - With Blood Control

Sol-Care Safety IV Catheters are developed to provide a vascular access to patients and at the same time reduce the risk of needle stick injuries and blood exposure. They are single-use indwelling device consisting of medical plastics, stainless steel needle and passive safety needle tip protection. The notch presented in the needle enables a quick blood return visualization. Available in straight with wings version. They are offered in soft polyurethane material, clear flashback chamber, anti-slips ribs and tab that helps on the catheter insertion and advancement with no technique change required by the user. They are dsigned to stand high pressure injection, up to 300psi. They are also color-code for easier catheter gauge identification, It is intended to be inserted into a patient’s peripheral vascular system for short term use of blood sampling or fluids administration. Their blood control feature, will prevent blood exposure immediately upon needle removal reducing the risk of bloodborne pathogens contamination.

They are compatible with ISO luers. Our products are Latex free, DEHP Free, non-toxic, non-pyrogenic and latex free

Indications: IV access to peripheral vascular system indicated for short term use to sample blood or administer fluid.

Intended user: Healthcare professional.

Precautions:

1. For proper use, clinicians must be trained in the practice of venipuncture and follow the INSTRUCTIONS FOR USE.

2. Observe Standard Precautions on all patients.

3. Aseptic technique, proper skin preparation, and continued protection of the insertion site are essential.

4. Product is sterile, non-toxic and non-pyrogenic unless package has been opened or damaged.

5. This product is DEHP free. This product does not contain natural rubber latex.

6. Single use only. Do not re-use.

7. Do not bend the needle when using the catheter system.

8. Do not use scissors at or near the insertion site.

9. Do not attempt to override or defeat the needle shielding mechanism.

10. Report needle sticks immediately and follow established protocol.

11. Immediately dispose of any needles that fail to shield, keeping the needlepoint away from the body and fingers at all times.

12. Do not attempt to reinsert a partially or completely withdrawn needle back into the catheter.

13. Re-use may lead to infection or other illness/injury.

14. Connectors used in conjunction with the product must comply with ISO 80369-7

15. Luer connections should not be left unattended due to potential of disconnection.

16. If the Disposable IV Catheter is indicated for power injection, catheter systems are suitable for use with power injectors set to a maximum pressure of 300 psi and within maximum flow

rate recommendations (see table), when the Vent fitting is removed, and a direct connection is made.

17. The patency of the catheter system must be assured immediately before power injecting. Measures should be taken to avoid kinking or obstructing the catheter system during power

injection to avoid product failure.

18. Use with power injector pressure greater than 300 psi may cause product leakage and/or damage to the product.

19. Ensure that the injector is properly calibrated and will automatically stop at a pressure which exceeds 300 psi.

20. When power injecting through the device with a luer adapter with dual port, replace any needleless cap on the unused port with a dead-end cap and tighten.

21. Flush the device using sterile normal saline prior to and immediately following the completion of power injection.

22. It is recommended that the device be changed according to facility policy or if the integrity of the device has been compromised.

23. Follow current institutional policies and procedures for catheter insertion, maintenance and removal.

24. The device can be used in the MRI environment.

Sol-M™ Blunt Fill Needle with Filter

The Sol-M Blunt Fill Needle with Filter is designed to reduce the risk of needlestick injuries to healthcare workers when preparing medication by removing the need for sharps. The 5-micorn filter is designed to restrain drawing of shattered particles when using ampoules.

For use when drawing medication and can also be used for addig medication in needless IV systems.
Features:
• Eliminates the unnecessary use of sharps
• Color-coded hubs for easy identification
• Needle hub is compatible with all Luer Lock and Luer Slip Tip syringes
• 5-micron filter is included to prevent the drawing of glass particles when using ampules
• Not manufactured with Latex, PVC and DEHP

Intended use: Sol-M™ Blunt Fill Needle is used in conjunction with a syringe as an
additive device for aspiration from multi-dose medicine vials or injection into I.V. Systems and pre-slit septum covering injection sites.

Intended user: Licensed healthcare professionals (HCP).

Cautions:
• Single use device. Re-use or use if the package is damaged may lead to infection or other illness/ injury.
• Sharp object. Risk of sharp injuries.

Note: In case particle are visible in the vial or ampoule it is recommended to discard the medication to prevent injections of those particles in the patient.

CE 2797

Sol-M® NRFit® Spinal Needle, Back-Cut Point, with introducer needle (Type : AN-S I)

Intended for spinal puncture and injection of liquid drugs into the subarachnoid space, the Sol-M® NRFit® spinal needles, with back-cut, adopt the ISO 80369-6, NRFit®, connector to help preventing potentially fatal misconnection risks.

The introducer needle allows for easy skin penetration and provides additional support to the spinal needle.

Sol-M® NRFit® Spinal Needles’ clear hub and rapid reflux enables anaesthesiologists to visualize CSF for proper needle placement.

Sol-M® NRFit® Spinal Needles are available in different sizes with lengths ranging from 38 mm to 120 mm and gauges from 18 G to 27 G.

  • Sharp bevel designed for low puncture force to help minimise tissue coring

  • High-quality stainless-steel needle for increased stability

  • Stylet clip provide identification of needle tip point orientation and reduce the risk of needle stylet falling out

  • Needle tip orientation indicator for identification of needle tip point orientation.

  • Clear needle hub for easy visualization of blood or CSF and detection of CSF flashback

  • Ergonomic needle hub design for an individual and safe handing position, better control of needle

  • Fitted stylet to reduce the risk of tissue coring

  • Colour-coded Needle Hub: easy to identify Needle Gauge

 

Intended use: Spinal puncture and injection of liquid drugs into the subarachnoid space.

Intended user: Professionally qualified anesthesiologist.

Cautions:

  • Do not use if the package is opened or damaged.

  • Read the instruction for use before using this product.

 

CE 0123

Distributed by Sol-Millennium Europe Sp. z o.o. Manufactured by Zhejiang Runqiang Medical Instruments Co., Ltd 599 Ruifeng, Street, Gaozhao District, Xiuzhou District, 314031 Jiaxing City.

NRFit® is a registered mark of GEDSA. NRFit® educational material used with permission of GEDSA, www.stayconnected.org

Sol-M® NRFit® Epidural Needle (Type AN-E)

Intended for epidural puncture, and injection of liquid drugs into the epidural space, the Sol-M® NRFit® Epidural needle with fixed wings adopts the ISO 80369-6, NRFit®, connector to help preventing potentially fatal misconnection risks.

Sol-M® NRFit® Epidural Needles with Fixed Wings provide an ergonomic grip for anaesthesiologists, enabling more control over needle insertion and depth. The needle tube has calibrated

needle-depth markings to illustrate depth. Sol-M® Epidural Needles with Fixed Wings are available in a series of combination of needle size and length.

  • High-quality stainless-steel epidural needle

  • Fitted color-coded plastic stylet

  • Fixed wings that give extra stability

  • Ergonomic needle hub for better control of needle

Intended use: Epidural puncture and injection of liquid drugs into the epidural space.

Intended user: Professionally qualified anesthesiologist.

Cautions:

  • Do not use if the package is opened or damaged.

  • Read the instruction for use before using this product.

 

CE 0123

Distributed by Sol-Millennium Europe Sp. z o.o. Manufactured by Zhejiang Runqiang Medical Instruments Co., Ltd 599 Ruifeng, Street, Gaozhao District, Xiuzhou District, 314031 Jiaxing City.

NRFit® is a registered mark of GEDSA. NRFit® educational material used with permission of GEDSA, www.stayconnected.org

Sol-M® NRFit® Combined Spinal and Epidural Anesthesia Mini-Kit (Type AS-E/ S II)

Intended for contemporary spinal and epidural puncture for spinal anesthesia followed by injection of liquid drugs into the epidural space each mini-kit includes a coordinated range of spinal and epidural needles, and epidural catheter, LOR syringe and antibacterial filters fitted with the ISO 80369-6, NRFit®, connector to reduce the risks of misconnections in regional anaesthesia.

Each mini-kit includes:

  • NRFit® Epidural needle,

  • NRFit® Spinal needle (AN-S II = pencil point),

  • NRFit® Epidural catheter + Catheter introducer guide,

  • NRFit® Catheter connector,

  • NRFit® LOR Syringe 10ml,

  • NRFit® Liquid filter 0.22μm,

  • Epidural Caution Label

Sol-M® NRFit® Spinal Needles’ clear hubs enable anaesthesiologists to visualize CSF for proper needle placement.

Sol-M® NRFit® Epidural Needles with Fixed Wings provide an ergonomic grip for anaesthesiologists, enabling more control over needle insertion and depth. The needle tube has calibrated needle-depth markings to illustrate depth.

Sol-M® NRFit® Epidural Catheter provides the precise balance of characteristics needed to get ease of placement, reliable patency, and optimum indwelling characteristics. Now this technology is available in a close-end, multiport, standard and wire reinforced catheter.

  • High-quality stainless-steel needle for increased stability

  • Spinal needle’s stylet clip provide identification of needle tip point orientation and reduce the risk of needle stylet falling out

  • Spinal needle’s tip orientation indicator for identification of needle tip point orientation.

  • Fitted color-coded plastic stylet

  • Epidural needle’s fixed wings that give extra stability

  • Ergonomic needle hub for better control of needle

  • Loss-of-resistance syringe for the identification of the epidural space

  • Epidural catheter available with soft and reinforced tip configurations

  • Liquid filter 0.22 micron for bacterial contamination prevention

 

Intended use: Spinal and epidural puncture, and injection of liquid drugs into the epidural space and the subarachnoid space.

Intended user: Professionally qualified anesthesiologist.

Cautions:

·       Never pull back the catheter through the epidural needle.

·       Do not use if the package is opened or damaged.

·       Read the instruction for use before using this product.

 

CE 0123

Distributed by Sol-Millennium Europe Sp. z o.o. Manufactured by Zhejiang Runqiang Medical Instruments Co., Ltd 599 Ruifeng, Street, Gaozhao District, Xiuzhou District, 314031 Jiaxing City.

NRFit® is a registered mark of GEDSA. NRFit® educational material used with permission of GEDSA, www.stayconnected.org

Sol-M® Spinal Needle, Back-cut Point (Type : AN-S I)

Sol-M® Spinal Needles’ clear hubs enable anaesthesiologists to visualize CSF reflux for proper needle placement.

The spinal anesthesia needle has a tightly fitting removable stylet that completely occludes the lumen to avoid block. The stylet is withdrawn after the spinal anesthesia needle has penetrated into the subarachnoid space for injecting anesthetic.

Sol-M® Spinal needle, with Back-cut point, are available in a series combination of needle size and length. The Sol-M™ Spinal Needle are available in different sizes with lengths ranging from 38 mm to 120 mm and gauges from 18 G to 27 G.

  • Sharp Back-cut Point designed for low puncture force

  • High-quality stainless-steel needle for increased stability

  • Stylet clip provide identification of needle tip point orientation and reduce the risk of needle stylet falling out

  • Needle tip orientation indicator for identification of needle tip point orientation

  • Clear needle hub for easy visualization of blood or CSF and detection of CSF flashback

  • Ergonomic needle hub design for an individual and safe handing position, better control of needle

  • Fitted Stylet to reduce the risk of tissue coring

  • Traditional Luer Lock female connection for compatibility with a wide range of devices, such has Luer and Luer Lock syringes

  • Colour-coded Needle Hub: easy to identify Needle Gauge

Intended use: Spinal puncture and injection of liquid drugs into the subarachnoid space.

Intended user: Professionally qualified anesthesiologist.

Cautions:

  • Do not use if the package is opened or damaged.

  • Read the instruction for use before using this product.

CE 0123

Distributed by Sol-Millennium Europe Sp. z o.o. Manufactured by Zhejiang Runqiang Medical Instruments Co., Ltd 599 Ruifeng, Street, Gaozhao District, Xiuzhou District, 314031 Jiaxing City.

Sol-M® Epidural Needle (Type AN-E)

Intended for epidural puncture, and injection of liquid drugs into the epidural space.

Sol-M® Epidural Needles with Fixed Wings provide an ergonomic grip for anaesthesiologists, enabling more control over needle insertion and depth. The needle tube has calibrated

needle-depth markings to illustrate depth.

Sol-M™ Epidural Needles with Fixed Wings are available in a series of combination of needle size and length.

  • High-quality stainless-steel epidural needle

  • Fitted color-coded plastic stylet

  • Fixed wings that give extra stability

  • Ergonomic needle hub for better control of needle

  • Traditional Luer Lock female connection for compatibility with a wide range of devices, such has Luer and Luer Lock syringes

Intended use: Epidural puncture and injection of liquid drugs into the epidural space.

Intended user: Professionally qualified anesthesiologist.

Cautions:

  • Do not use if the package is opened or damaged.

  • Read the instruction for use before using this product.

CE 0123

Distributed by Sol-Millennium Europe Sp. z o.o. Manufactured by Zhejiang Runqiang Medical Instruments Co., Ltd 599 Ruifeng, Street, Gaozhao District, Xiuzhou District, 314031 Jiaxing City.

Sol-M® NRFit® Spinal Needle, Back-Cut Point (Type : AN-S I)

Intended for spinal puncture and injection of liquid drugs into the subarachnoid space, the Sol-M® NRFit® spinal needles, with back-cut, adopt the ISO 80369-6, NRFit®, connector to help preventing potentially fatal misconnection risks.

Sol-M® NRFit® Spinal Needles’ clear hub and rapid reflux enables anaesthesiologists to visualize CSF for proper needle placement.

Sol-M® NRFit® Spinal Needles are available in different sizes with lengths ranging from 38 mm to 120 mm and gauges from 18 G to 27 G.

  • Sharp bevel designed for low puncture force to help minimise tissue coring

  • High-quality stainless-steel needle for increased stability

  • Stylet clip provide identification of needle tip point orientation and reduce the risk of needle stylet falling out

  • Needle tip orientation indicator for identification of needle tip point orientation.

  • Clear needle hub for easy visualization of blood or CSF and detection of CSF flashback

  • Ergonomic needle hub design for an individual and safe handing position, better control of needle

  • Fitted stylet to reduce the risk of tissue coring

  • Colour-coded Needle Hub: easy to identify Needle Gauge

 

Intended use: Spinal puncture and injection of liquid drugs into the subarachnoid space.

Intended user: Professionally qualified anesthesiologist.

Cautions:

  • Do not use if the package is opened or damaged.

  • Read the instruction for use before using this product.

 

CE 0123

Distributed by Sol-Millennium Europe Sp. z o.o. Manufactured by Zhejiang Runqiang Medical Instruments Co., Ltd 599 Ruifeng, Street, Gaozhao District, Xiuzhou District, 314031 Jiaxing City.

NRFit® is a registered mark of GEDSA. NRFit® educational material used with permission of GEDSA, www.stayconnected.org

Sol-M® NRFit® Spinal Needle, Pencil Point, with introducer needle (Type : AN-S II)

Intended for spinal puncture and injection of liquid drugs into the subarachnoid space, the Sol-M® NRFit® spinal needles, with pencil point, adopt the ISO 80369-6, NRFit®, connector to help preventing potentially fatal misconnection risks.

The introducer needle allows for easy skin penetration and provides additional support to the spinal needle.

Sol-M® NRFit® Spinal Needles’ clear hub and rapid reflux enables anaesthesiologists to visualize CSF for proper needle placement.

Sol-M® NRFit® Spinal Needles with introducer needle are available in different sizes with lengths ranging from 75 mm to 120 mm and gauges from 22 G to 27 G.

  • Pencil Point's atraumatic puncture and optimal gliding properties minimize possible injuries and prevent foreign bodies and tissue particles from being carried into the subarachnoid space, while reducing the incidence of post-dural puncture headache (PDPH)

  • High-quality stainless-steel needle for increased stability

  • Stylet clip provide identification of needle tip point orientation and reduce the risk of needle stylet falling out

  • Needle tip orientation indicator for identification of needle tip point orientation.

  • Clear needle hub for easy visualization of blood or CSF and detection of CSF flashback

  • Ergonomic needle hub design for an individual and safe handing position, better control of needle

  • Fitted stylet to reduce the risk of tissue coring

  • Colour-coded Needle Hub: easy to identify Needle Gauge

 

Intended use: Spinal puncture and injection of liquid drugs into the subarachnoid space.

Intended user: Professionally qualified anesthesiologist.

Cautions:

  • Do not use if the package is opened or damaged.

  • Read the instruction for use before using this product.

CE 0123

Distributed by Sol-Millennium Europe Sp. z o.o. Manufactured by Zhejiang Runqiang Medical Instruments Co., Ltd 599 Ruifeng, Street, Gaozhao District, Xiuzhou District, 314031 Jiaxing City.

NRFit® is a registered mark of GEDSA. NRFit® educational material used with permission of GEDSA, www.stayconnected.org

Sol-Care™ Safety IV Catheter Closed System

Sol-Care™ Safety IV Catheter Closed System is single use indwelling device consists of medical plastics, stainless steel needle, wings and extension sets. The device can be single port and dual port with needle free port. It is used to insert into the human peripheral vascular system for
clinical infusion.
The device features passive safety mechanism that offers protection from needle stick injury after the needle is withdrawn from the patient.

Intended use: The device is intended for short term use in the peripheral vascular and subcutaneous system and provides access for the administration of intravenous fluids, medication, blood derivates or the withdrawal of blood samples. Closed peripheral venous catheter can stay inserted as long as clinically indicated for short term therapy but the only if there is no any sign of phlebitis or catheter occlusion or any signs of complications. This catheter may be used for any patient population with consideration given to adequacy of vascular anatomy and appropriateness of procedure.

Intended user: Licensed healthcare professionals (HCP).

Cautions:
• Consult instruction for use before using this device
• Users must be trained by a healthcare professional and follow the Instructions For Use.
Failure to follow these instructions could result in serious injury to the patient and/or clinician.
• Sharp object. Risk of sharp injuries.
• Do not use if the unit package is damaged or opened.
• Device for single use only: do not sterilize and/or use again, in order not to compromise its performances or cause possible cross contamination by other patients.

CE0197

Distributed by Sol-Millennium Europe Sp. z o.o. Manufactured by Fujian Bestway Medical Polymer
Corporation, Room 02, 17th Floor, West District of Jinyuan Grand Plaza, No. 68 Guangda Road,
Taijiang District, Fuzhou, 350005 Fujian P.R.China

  • 1 of 7